Per page:  

Item #: 753040539
EMC Filter Surge Protection Device
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, 1 or 2-channel operation, 3 enabling current paths, nominal input voltage: 230 V AC/DC, plug-in spring cage terminal block.
  • Up to Cat 4/PL e according to EN ISO 13849-1, SILCL 3 according to EN 62061, SIL 3 according to IEC 61508
  • Manually monitored and automatic activation in a single device
  • Basic insulation
  • 3 enabling current paths, 1 signaling current path
  • Single and two-channel control
quantity

Item #: 753037837
Lightning/Surge Arrester
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, single or two-channel operation, 2 enabling current paths, nominal input voltage of 24 V AC/DC, plug-in screw terminal blocks.
  • Up to Cat 4/PL e according to EN ISO 13849-1, SILCL 3 according to EN 62061, SIL 3 according to IEC 61508
  • Manually monitored and automatic activation in a single device
  • Basic insulation
  • 2 enabling current paths, 1 signaling current path
  • Single and two-channel control
quantity

Item #: 753040480
Lightning/Surge Arrester
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, single or two-channel operation, 3 enabling current paths, nominal input voltage of 42 to 48 V AC/DC, plug-in screw terminal blocks.
  • Up to Cat 4/PL e according to EN ISO 13849-1, SILCL 3 according to EN 62061, SIL 3 according to IEC 61508
  • Manually monitored and automatic activation in a single device
  • Basic insulation
  • 3 enabling current paths, 1 signaling current path
  • Single and two-channel control
quantity

Item #: 900142974
Lightning/Surge Arrester
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, single or two-channel operation, 3 enabling current paths, nominal input voltage of 120 V AC/DC, plug-in screw terminal blocks.
  • Up to Cat 4/PL e according to EN ISO 13849-1, SILCL 3 according to EN 62061, SIL 3 according to IEC 61508
  • Manually monitored and automatic activation in a single device
  • Basic insulation
  • 3 enabling current paths, 1 signaling current path
  • Single and two-channel control
quantity

Item #: 753040514
Inline Terminal Block
Multifunctional safety relay for emergency stop, safety doors, and light gridmonitoring up to SIL 3, Cat 4, PL e, automatically or manually monitored activation, 4 N/O contacts, 3 safety functions, 2 shutdown levels, fixed push-in terminal blocks.
  • Up to Cat 4/PL e according to EN ISO 13849-1, SILCL 3 according to EN 62061, SIL 3 according to IEC 61508
  • 3 safety functions in one device
  • Low housing width of only 22.5mm
  • No software configuration required
  • Also available with push-in connection
quantity

Item #: 753040535
Inline Terminal
Multifunctional safety relay for emergency stop and safety doors up to SIL 3, Cat. 4, PL e, automatically or manually monitored activation, 4 N/O contacts, 3 safety functions, 2 shutdown levels, plug-in spring cage terminal block.
  • Up to Cat 4/PL e according to EN ISO 13849-1, SILCL 3 according to EN 62061, SIL 3 according to IEC 61508
  • 3 safety functions in one device
  • Low housing width of only 22.5mm
  • No software configuration required
  • Also available with push-in connection
quantity

Item #: 753040575
Field Multiplexer
Multifunctional safety relay for emergency stop and safety doors up to SIL 3, Cat 4, PL e, automatically or manually monitored activation, 4 N/O contacts, 3 safety functions, 2 shutdown levels, fixed push-in terminal blocks.
  • Up to Cat 4/PL e according to EN ISO 13849-1, SILCL 3 according to EN 62061, SIL 3 according to IEC 61508
  • 3 safety functions in one device
  • Low housing width of only 22.5mm
  • No software configuration required
  • Also available with push-in connection
quantity

Item #: 753040526
Inline Terminal
Multifunctional safety relay for emergency stop and safety doors up to SIL 3, Cat. 4, PL e, automatically or manually monitored activation, 4 N/O contacts, 3 safety functions, 2 shutdown levels, fixed push-in terminal blocks.
  • Up to Cat 4/PL e according to EN ISO 13849-1, SILCL 3 according to EN 62061, SIL 3 according to IEC 61508
  • 3 safety functions in one device
  • Low housing width of only 22.5mm
  • No software configuration required
  • Also available with push-in connection
quantity

Item #: 753040519
Bus Coupler
Multifunctional safety relay for emergency stop and safety doors up to SIL 3, Cat. 4, PL e, automatically or manually monitored activation, 4 N/O contacts, 3 safety functions, 2 shutdown levels, plug-in screw terminal block.
  • Up to Cat 4/PL e according to EN ISO 13849-1, SILCL 3 according to EN 62061, SIL 3 according to IEC 61508
  • 3 safety functions in one device
  • Low housing width of only 22.5mm
  • No software configuration required
  • Also available with push-in connection
quantity

Item #: 753040504
Inline Terminal
Multifunctional safety relay for emergency stop, safety doors, and light grid up to SIL 3, Cat. 4, PL e, automatically or manually monitored activation, 4 N/O contacts, 3 safety functions, 2 shutdown levels, plug-in screw terminal block.
  • Up to Cat 4/PL e according to EN ISO 13849-1, SILCL 3 according to EN 62061, SIL 3 according to IEC 61508
  • 3 safety functions in one device
  • Low housing width of only 22.5mm
  • No software configuration required
  • Also available with push-in connection
quantity