NZ2EXSS2-8TE Mitsubishi Safety Module
Item #: 803023491
CC IE FIELD SAFETY REMOTE OUTPUT 8 PTS
NZ2GFSS2-8D Mitsubishi Safety Module
Item #: 803023492
CC IE FIELD SAFETY REMOTE INPUT, 8IN
NZ2GFSS2-8TE Mitsubishi Safety Module
Item #: 803023490
CC IE FIELD SAFETY REMOTE OUTPUT, 8 OUT
NZ2GFSS2-16DTE Mitsubishi Safety Module
Item #: 803023494
CC IE FIELD SAFETY REMOTE I/O, 8IN4OUT
NZ2GFSS2-32D Mitsubishi Safety Module
Item #: 803023493
CC IE FIELD SAFETY REMOTE INPUT 32 PTS
2963718 Phoenix Contact PSR-SCP- 24UC/ESM4/2X1/1X2
Item #: 753017784
Ferrule
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, single or two-channel operation.
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, single or two-channel operation.
- Up to Cat 4/PL e according to EN ISO 13849-1, SILCL 3 according to EN 62061, SIL 3 according to IEC 61508
- Single and two-channel control
- 2 enabling current paths, 1 signaling current path
2963750 Phoenix Contact PSR-SCP- 24UC/ESA4/2X1/1X2
Item #: 753017788
Interface Converter
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, single or two-channel operation, 2 enabling current paths, nominal input voltage of 24 V AC/DC, plug-in screw terminal blocks.
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, single or two-channel operation, 2 enabling current paths, nominal input voltage of 24 V AC/DC, plug-in screw terminal blocks.
- Up to Cat 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
- Single and two-channel control
- 2 enabling current paths, 1 signaling current path
- Manually monitored and automatic activation in a single device
2963763 Phoenix Contact PSR-SCP- 24UC/ESA4/3X1/1X2/B
Item #: 753017789
Safety Module
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, single or two-channel operation, 3 enabling current paths, nominal input voltage of 24 V AC/DC, plug-in screw terminal blocks.
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, single or two-channel operation, 3 enabling current paths, nominal input voltage of 24 V AC/DC, plug-in screw terminal blocks.
- Up to Cat 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
- Single and two-channel control
- 3 enabling current paths, 1 signaling current path
- Manually monitored and automatic activation in a single device