Per page:  

Item #: 753005303
Contact insert
Safety relay for emergency stop and safety door and light grid monitoring up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, single or two-channel operation, 3 enabling current paths, nominal input voltage of 24 V AC/DC, plug-in screw terminal blocks.
  • Manually monitored and automatic activation
  • Up to Cat 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
  • Three enabling and one signaling current path
  • Single and two-channel control
quantity

Item #: 900115010
Industrial Ethernet Switch
Safety relay for emergency stop, safety door, and magnetic switches, as well as light grid, up to SIL 3 or Cat 4, PL e according to EN ISO 13849, 2 N/O contacts, TBUS interface, automatic or manual activation, plug-in screw connection terminal blocks.
  • Up to Cat 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
  • Single and two-channel control
  • 2 enabling current paths, 1 signaling current path
  • For emergency stop and safety door monitoring, plus evaluation of light grids
  • Modular system with TBUS extension
quantity

Item #: 753036947
Industrial Ethernet Switch
Safety relay for emergency stop, safety door, and magnetic switches, as well as light grid, up to SIL 3 or Cat. 4, PL e according to EN ISO 13849, 2 N/O contacts, TBUS interface, automatic or manual activation, plug-in spring-cage connection terminal blocks.
  • Up to Cat 4/PL e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
  • Single and two-channel control
  • 2 enabling current paths, 1 signaling current path
  • For emergency stop and safety door monitoring, plus evaluation of light grids
  • Modular system with TBUS extension
quantity

Item #: 900103293
Lightning/Surge Arrester
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, automatic or manual activation, 2 N/O contacts dropout delayed from 0.1 s to 30 s, plug-in screw connection terminal blocks.
  • Maximum of 3 undelayed and 2 dropout delay contacts
  • Manually monitored and automatic activation
  • Up to Cat 3/4 and PL d/e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
  • For emergency stop and safety door monitoring, plus evaluation of light grids
  • Protective labels to prevent manipulation of the set time or electronic protection against manipulation
  • Single and two-channel control|Adjustable delay time of 0.2 s to 300 s
quantity

Item #: 753036380
Inline Terminal
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, automatic or manual activation, 2 N/O contacts dropout delayed from 0.1 s to 30 s, plug-in spring-cage connection terminal blocks.
  • Maximum of 3 undelayed and 2 dropout delay contacts
  • Manually monitored and automatic activation
  • Up to Cat 3/4 and PL d/e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
  • For emergency stop and safety door monitoring, plus evaluation of light grids
  • Protective labels to prevent manipulation of the set time or electronic protection against manipulation
  • Single and two-channel control|Adjustable delay time of 0.2 s to 300 s
quantity

Item #: 753036383
Lightning/Surge Arrester
Interface module, for up to four safety sensors/switches with N/O or N/C contact, screw connection.
  • 4 Two-channel N/O or N/C contact inputs
  • Up to Cat 3/PL d according to ISO 13849-1, SILCL 2 according to IEC 62061, SIL 2 according to IEC 61508
  • 4 PLC diagnostic outputs for evaluating the switching state of the safety sensors
  • 4 LEDs as status indicators for the relevant sensor/switch
  • PSR-TBUS connection
quantity