Per page:  

Item #: 900103293
Lightning/Surge Arrester
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, automatic or manual activation, 2 N/O contacts dropout delayed from 0.1 s to 30 s, plug-in screw connection terminal blocks.
  • Maximum of 3 undelayed and 2 dropout delay contacts
  • Manually monitored and automatic activation
  • Up to Cat 3/4 and PL d/e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
  • For emergency stop and safety door monitoring, plus evaluation of light grids
  • Protective labels to prevent manipulation of the set time or electronic protection against manipulation
  • Single and two-channel control|Adjustable delay time of 0.2 s to 300 s
quantity

Item #: 753036380
Inline Terminal
Safety relay for emergency stop and safety door monitoring up to SIL 3 or Cat 4, PL e according to EN ISO 13849, automatic or manual activation, 2 N/O contacts dropout delayed from 0.1 s to 30 s, plug-in spring-cage connection terminal blocks.
  • Maximum of 3 undelayed and 2 dropout delay contacts
  • Manually monitored and automatic activation
  • Up to Cat 3/4 and PL d/e according to ISO 13849-1, SILCL 3 according to IEC 62061, SIL 3 according to IEC 61508
  • For emergency stop and safety door monitoring, plus evaluation of light grids
  • Protective labels to prevent manipulation of the set time or electronic protection against manipulation
  • Single and two-channel control|Adjustable delay time of 0.2 s to 300 s
quantity

Item #: 753036383
Lightning/Surge Arrester
Interface module, for up to four safety sensors/switches with N/O or N/C contact, screw connection.
  • 4 Two-channel N/O or N/C contact inputs
  • Up to Cat 3/PL d according to ISO 13849-1, SILCL 2 according to IEC 62061, SIL 2 according to IEC 61508
  • 4 PLC diagnostic outputs for evaluating the switching state of the safety sensors
  • 4 LEDs as status indicators for the relevant sensor/switch
  • PSR-TBUS connection
quantity

Item #: 753037836
Plug-In Bridge
Safe coupling relay for SIL 2 high and low-demand applications couples digital output signals to the I/O 2 enabling current paths 1 alarm contact module for safe state off applications integrated test pulse filter plug-in screw terminal blocks width: 17.5 mm
  • Narrow 17.5 mm housing
  • Up to SIL 2 according to EN 61508
  • Forcibly guided contacts according to EN 50205
  • Easy proof test according to IEC 61508 thanks to integrated signal contact
  • Long service life thanks to filtering of controller test pulses
  • Two enabling current paths
  • Couples digital output signals from fail safe controllers to I/O devices (valves, etc.) for electrical isolation and power adaptation
quantity

Item #: 753037839
Plug-In Bridge
Safe coupling relay for SIL 2 high and low-demand applications couples digital output signals to the I/O 2 enabling current paths 1 alarm contact module for safe state off applications integrated test pulse filter plug-in spring-cage terminal blocks width: 17.5 mm
  • Narrow 17.5 mm housing
  • Up to SIL 2 according to EN 61508
  • Forcibly guided contacts according to EN 50205
  • Easy proof test according to IEC 61508 thanks to integrated signal contact
  • Long service life thanks to filtering of controller test pulses
  • Two enabling current paths
  • Couples digital output signals from fail safe controllers to I/O devices (valves, etc.) for electrical isolation and power adaptation
quantity

Item #: 753037838
Hybrid Motor Starter
Safe coupling relay for SIL3 high and low demand applications connects digital output signals to the I/O 2 enabling current paths 1 signal contact module for safe state off applications integrated test pulse filter plug-in spring-cage connection width: 17.5 mm
  • Easy proof test according to IEC 61508 thanks to integrated signal contact
  • Forcibly guided contacts according to EN 50205
  • Long service life thanks to filtering of controller test pulses two enabling current paths
quantity

Item #: 753036098
D-Sub Bus Connector
Two-channel speed and downtime monitor up to SIL 3 or Cat. 4 PL e according to EN ISO 13849 4 N/O contacts suitable for connecting incremental encoders and initiators plug-in spring-cage connection terminal blocks width: 45 mm
  • Standard sensors can be connected
  • Up to SIL 3 according to IEC 61508
  • Easy configuration via software
quantity

Item #: 753040511
Double Level Terminal Block
  • Easy proof test according to IEC 61508 thanks to integrated signal contact
  • Installation in zone 2 permitted
  • Couples digital output signals from fail safe controllers to Input/output devices for electrical isolation and power adaptation
quantity

Item #: 753040525
Lightning/Surge Arrester
  • Easy proof test according to IEC 61508 thanks to integrated signal contact
  • Installation in zone 2 permitted
  • Couples digital output signals from fail safe controllers to Input/output devices for electrical isolation and power adaptation
quantity

Item #: 753036363
Interface Module
Coupling relay for SIL 3 high/low demand applications couples digital output signals to the periphery 1 enabling current path 1 signal contact module for safe state off applications test pulse filter fuse plug-in screw connection 17.5 mm width
  • Forcibly guided contacts according to EN 50205
  • Easy proof test according to IEC 61508 thanks to integrated signal contact
  • One enabling current path
quantity