Per page:  

Item #: 753036093
Coupling Relay
Single-channel contact extension with TBUS interface 4 N/O contacts 1 N/C contact 1 confirmation current path the contacts have a release delay (0.3 s - 3 s) Cat. 3 PL e according to EN ISO 13849 plug-in terminal blocks with screw connection width: 22.5 mm
  • Contact Extension With PSR-TBUS Connection
  • 4 Enabling Current paths
  • 1 Signaling Current Path
  • Single-channel wiring
  • Safe isolation
quantity

Item #: 753036088
Surge Protection Plug
Single-channel contact extension with TBUS interface 4 N/O contacts 1 N/C contact 1 confirmation current path the contacts have a release delay (0.3 s - 3 s) Cat. 3 PL e according to EN 13849 plug-in terminal blocks with spring-cage connection width: 2.5 mm
  • Contact Extension With PSR-TBUS Connection
  • 4 Enabling Current paths
  • 1 Signaling Current Path
  • Single-channel wiring
  • Safe isolation
quantity

Item #: 753037221
Marker for Terminal Block
Universal safety relay with positively driven contacts 3 N/O contacts 3 N/C contacts plug-in terminal blocks with screw connection width: 22.5 mm
  • Like all PSR Safety Relays, Equipped with Forcibly Guided Contacts According to EN 50205
  • Single-channel Control
quantity

Item #: 753037222
Power Supply Unit
Universal safety relay positively driven contact 3 N/O contacts 3 N/C contacts plug-in terminal blocks with spring-cage connection width: 22.5 mm
  • Like all PSR Safety Relays, Equipped with Forcibly Guided Contacts According to EN 50205
  • Single-channel Control
quantity

Item #: 753036957
Feed-Through Terminal Block
The sensor box PSR-SACB for safety limit switches safely interconnects up to 4 connected limit switches each with 1 N/C contact and 1 N/O contact to a safety relay combination e.g. PSR-SDC4 cable length: 5 m
  • Safety in the field
  • Molded housing and high degree of protection
  • Flexible, distributed bundling of signals in one master cable
  • Increased machine availability and easy diagnostics
  • Save time
quantity

Item #: 753036956
Spring Cage Ground Terminal Block
The sensor box PSR-SACB for safety limit switches safely interconnects up to 4 connected limit switches each with 1 N/C contact and 1 N/O contact to a safety relay combination e.g. PSR-SDC4 cable length: 10 m
  • Safety in the field
  • Molded housing and high degree of protection
  • Flexible, distributed bundling of signals in one master cable
  • Increased machine availability and easy diagnostics
  • Save time
quantity

Item #: 753037220
Extension Module
Universal safety relay with positively driven contacts 5 N/O contacts 1 N/C contact plug-in terminal blocks with spring-cage connection width: 22.5 mm
  • Like all PSR Safety Relays, Equipped with Forcibly Guided Contacts According to EN 50205
  • Single-channel Control
quantity

Item #: 753036363
Interface Module
Coupling relay for SIL 3 high/low demand applications couples digital output signals to the periphery 1 enabling current path 1 signal contact module for safe state off applications test pulse filter fuse plug-in screw connection 17.5 mm width
  • Forcibly guided contacts according to EN 50205
  • Easy proof test according to IEC 61508 thanks to integrated signal contact
  • One enabling current path
quantity

Item #: 753036364
Interface Converter
Coupling relay for SIL 3 high/low demand applications couples digital output signals to the periphery 1 enabling current path 1 signal contact module for safe state off applications test pulse filter fuse plug-in spring-cage connection 17.5 mm width
  • Forcibly guided contacts according to EN 50205
  • Easy proof test according to IEC 61508 thanks to integrated signal contact
  • One enabling current path
quantity

Item #: 900121451
Partition Plate
Ex-i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
  • Power supply and error indication possible via DIN rail connector
  • 3-way electrical isolation
  • Direction of operation can be selected (operating or closed circuit current behavior)
quantity