2865340 Phoenix Contact MACX MCR-EX-SL-RPSSI-I
Item #: 900117046
Connector
Ex i repeater power supply and input signal conditioner, HART. Transmits supplied or active 0/4 - 20 mA signals from the hazardous area to a load (active or passive) in the safe area. 3-way electrical isolation; SIL 2 according to IEC 61508, with screw connection.
Ex i repeater power supply and input signal conditioner, HART. Transmits supplied or active 0/4 - 20 mA signals from the hazardous area to a load (active or passive) in the safe area. 3-way electrical isolation; SIL 2 according to IEC 61508, with screw connection.
- Bidirectional HART signal transmission
- Power supply possible via DIN rail connector
- Minimal power dissipation
- High transmission accuracy Error indication according to NAMUR NE 43
2865434 Phoenix Contact MACX MCR-EX-SL-NAM-R
Item #: 900128457
End Cover
Relay signal output; Reversible direction of action; Line fault detection (LFD), can be activated/deactivated, error message signaled by red flashing LED with de-excitation of output relay.
Relay signal output; Reversible direction of action; Line fault detection (LFD), can be activated/deactivated, error message signaled by red flashing LED with de-excitation of output relay.
- Power supply and error indication possible via DIN rail connector
- LED indicators for supply voltage, switching state, and malfunction according to NAMUR NE 44
- Relay signal output (PDT)
2865463 Phoenix Contact MACX MCR-EX-SL-NAM-2T
Item #: 753039526
Feed-Through Terminal Block
Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Ex i NAMUR isolating amplifier For operating proximity sensors and switches in Ex areas. The signals are transmitted via 2 transistor outputs (passive) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
- Power supply and error indication possible via DIN rail connector
- Up to SIL 2 according to EN 61508
- Installation in zone 2, protection type "n" (EN 60079-15) permitted
- Signal output 2 can also be used as an error signaling output
- Line fault detection (LFD), can be activated/deactivated, error indicated by red flashing LED with disabling of transistor output
- 4-way electrical isolation
- Direction of operation can be selected
2924087 Phoenix Contact MACX MCR-EX-SL-2NAM-RO-SP
Item #: 900121451
Partition Plate
Ex-i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
Ex-i NAMUR isolating amplifier, 2-channel. For operating proximity sensors and switches in Ex areas. The signals are transmitted via relay outputs (N/O contact) to the safe area. Line fault detection (LFD), 3-way isolation, SIL 2.
- Power supply and error indication possible via DIN rail connector
- 3-way electrical isolation
- Direction of operation can be selected (operating or closed circuit current behavior)
2924676 Phoenix Contact MACX MCR-EX-SL-RPSS-2I-2I-SP
Item #: 900177886
Extension Module
2-channel; Bidirectional transmission of digital HART communication signals; Plug-in screw or push-in connection technology, with integrated sockets for HART communicators.
2-channel; Bidirectional transmission of digital HART communication signals; Plug-in screw or push-in connection technology, with integrated sockets for HART communicators.
- 2-channel
- HART-capable
- Power supply possible via DIN rail connector
- Plug-in connection terminals, push-in connection technology
- Minimal power dissipation